Power Supply
Units shipped to the USA include a 12 V, 1.5 A, 120 VAC power supply. Contact the
factory if you require a different power supply. In an emergency, the Model E-1A can
accept power supplies within the following ranges:
12–24 VDC, either polarity, 1.5 A
9–18 VAC, 1.5 A
Audio Wiring
The ANALOGDIGITAL switch selects which input is active, but both outputs remain active.
Analog I/O
Set the ANALOGDIGITAL switch to ANALOG.
Figure 3-2 Analog connection
The eight channel inputs and outputs are TRS insert jacks. The Model E-1A receives
signal on the Tip and sends the return from the Ring.
When the Model E-1A is off, the audio signal passes through unaltered, so the unit
may be left patched when not in use.
The Model E-1A can be connected to the insert or line level input jacks.